Mark  H.

Mark H. Job Checkin

Performed diagnostic on 20yr trane heat pump, upon arrival customer explained he had a company out during spring and added refrigerant, stated unit is short cycling now, inspected outdoor unit and hooked up gauges, next inspected air handler in basement, blower wheel impacted, checked filter, evap coil heavily rusted and can see signs of oil, checked tstst, cycled to heat mode, checked heat strips amps, upon checking outdoor unit , unit is short cycling every 20sec, suction pulling down to vacuum, explained to customer unit have a failed outdoor txv as well as possible leak dew to oil on evap coil, explained r22 is obsolete as of 1/1/2020, highly recommend install supervisor, customer approved, schedule for today, customer only has aux heat at the moment, spoke with customer about home care as well as indoor air quality


Jose L.

Jose L. Job Checkin

Home inspection


Jason B.

Jason B. Job Checkin

customer has home warranty, but they were unable to come for nearly 2 weeks. Found a bad igniter and replaced with a universal hot rod igniter. Tested system and everything running. The blower motor has a rubbing noise, but I could not see any issues. this may be a sign of failure. Thank you for choosing certified and we look forward to being able to serve you for future project should you have a need.


Johan R.

Johan R. Job Checkin

For this job, we worked on fixing the wiring in a outlet box in the living room. previous electrician did not pigtail wires. Instead, he backstabbed the outlets and used a jumper from one outlet to another. one of the neutrals coming in was loose due to the backstab method which caused the rest of the circuit to not work. we fixed the wiring and reconnected the outlets. Everything is working properly. left estimates to redevice the house to avoid this issue in the future.


Austin M.

Austin M. Job Checkin

Troubleshot and installed a new homeowner provided wafer light and two new Gfci outlets in the kitchen


Ben L.

Ben L. Job Checkin

Replace 2 flood lights


Nicholas B.

Nicholas B. Job Checkin

Customer had a leak on main service line approximately 3 feet from the meter. Cut out damage section of pipe and replaced.


Daniel R.

Daniel R. Job Checkin

Tech arrived to no heat call for basement system. System is approximately 2/3 years heat pump system servicing downstairs. On arrival found low voltage blown. Checked all thermostat wiring inside and out, and found no signs for direct shorts or any wires touching metal or ground. Replaced fuse and watched operations. System did not replicate scenario after replacing fuse. Found outdoor temperature sensor partially pinched in fan area, moved to chase where wiring is designated. Contacter is within specs at this time. Notified partial discoloring at thermostat. System does not have water protection safeties up to TE’s standards. Verified heat strips are operational. Brought recommendations to customer. Customer agreed to sign up for HomeCare on two systems in home. Tech replaced customer provided customers thermostat. No warranty on thermostat outside of warranty. Flood protection waiver noted. Replaced 16x20x1 filter for basement and replaced customer supplied 20x20x1 upstairs. Thank


Michael U.

Michael U. Job Checkin

For this job we’ve rented leak detection services in the front yard of the home. Homeowner showed up after we arrived on scene. There is water present in the front yard however, once we are finally able to isolate the water main service at the meter and the shut off in the crawlspace we observed the meter quit spinning entirely upon further investigation. We discovered a toilet that is constantly running in the master bathroom homeowner was unaware of this as they are not living at the residence at this point because the home is under construction.


Daniel R.

Daniel R. Job Checkin

Tech arrived to problem call for entire home. System is a zoned system located in upstairs closet servicing entire home. Both thermostats have power and are actively telling the system to come on. Inspected indoor unit. Unit was not running at all. Found zone board LEDs not lit up as intended. Verified zone board has incoming power and outgoing R on thermostats. Zone board is not able to recognize incoming calls from thermostat therefore not running. Found that the zone board does not have a dedicated transformer which more than likely caused failure of the zone board. Jumped out wires to bypass zone board and test system. System did come on inside and out. System only has a float switch in pan and no other safeties. Highly recommended adding wet switch and safety switches along with cleaning indoor cabinet, blower compartment and drain flush. Checked outdoor unit. Unit in full operation, refrigerant pressures within specs. Outdoor capacitor is out of specs at this time. Brought recomm


Jonathan M.

Jonathan M. Job Checkin

Found that the shower valve was slowly leaking. Found that the water pressure was 95psi. Found that the thermal expansion tank was leaking. Replaced shower cartridge in the upstairs hall shower. Replaced prv and thermal expansion tank. 2years parts and labor warranty.


David M.

David M. Job Checkin

60a 240V for the new Tesla Car Charger Installing (1) Tesla Car Charger on the preferred location by the customer


Ben L.

Ben L. Job Checkin

Added outlet in kitchen


Karl S.

Karl S. Job Checkin

Replaced water pressure regulator and two attic water heaters


Mark  H.

Mark H. Job Checkin

Performed diagnostic on 5yr old carrier unit, upon arrival customer stated unit was leaking water, checked drain line, checked ok , poured water in primary drain pan and found leaking around the bottom, found crack on seal of pan, recommend replacing drain pan, checked blower motor, found blower wheel impacted, recommend pulling and cleaning, evap coil impacted as well, recommend cleaning, checked outdoor unit, condenser coil impacted as well, recommend cleaning, checked capacitor, contactor, spoke with customer about wet switch for extra safety on water issues, also spoke about high power UV lights, also recommend home care, customer chose option B without home care, went to parts house and picked up drain pan, returned and pumped refrigerant inside compressor, cut out evap coil, replaced drain pan, made sure there was no leaks, pressurized with nitrogen, no leaks, pulled vacuum, released refrigerant back into system, pulled and cleaned blower wheel, chemical cleaned condenser coil,